Quartz Engineering Solutions

High-Pressure Quartz Tube Sealing Guide

Technical Guide for Sealing Quartz Tubes in High-Pressure Conditions (โ‰ฅ10MPa)
Selection, Installation & Verification Procedures for Quartz, Alumina, and Sapphire Tubes

1. Seal Type Comparison Table

Seal TypeMax PressureTemp RangeReusableTube Diameter RangeRecommended Use Case
Metal Flange + Conical Sealโ‰ค30 MPa-200 ~ 500 ยฐCโœ“5โ€“100 mmHigh-pressure reactors requiring frequent access
Glass Fusion Sealโ‰ค15 MPaโ‰ค450 ยฐCโœ—3โ€“50 mmPermanent sensor encapsulation
Hydraulic Cold Compressionโ‰ค100 MPa-273 ~ 1000 ยฐCโœ—3โ€“20 mm (thick wall)Extreme pressure/cryogenic applications
Metallized Brazingโ‰ค50 MPaโ‰ค1000 ยฐCโœ—3โ€“20 mmAerospace and defense-grade reliability

2. Metal Flange with Conical Seal (Recommended Method)

1. Required Components

  • Flange Material: Inconel 718 (corrosion-resistant nickel alloy)
  • Seal Gasket: Annealed copper (1 mm thick, HV50 hardness)
  • Conical Angle: 20ยฐ ยฑ 0.5ยฐ (must match tube precision-ground taper)

2. Installation Procedure

โ‘  Preparation
  • Flame polish quartz tube ends to eliminate microcracks
  • Mirror-polish flange taper surface (Ra โ‰ค 0.8 ฮผm)
โ‘ก Assembly
  1. Place the copper gasket on the flange cone
  2. Apply high-temp vacuum grease (e.g., Apiezon N) to the tubeโ€™s taper
  3. Tighten bolts progressively using a hydraulic torque wrench

Bolt Torque Schedule (for M6 bolts):

StageTorque (Nยทm)Dwell Time
Preload105 min
Mid2010 min
Final3030 min

3. Leak Testing Criteria

  • Helium Leak Rate: โ‰ค 1ร—10โปโธ mbarยทL/s
  • Pressure Hold Test: 15 MPa for 1 hour, pressure drop <1%

3. Safety Precautions

1. Explosion Protection

  • 6 mm polycarbonate blast shield around the tube (with IR camera window optional)
  • Install mechanical pressure relief valve (setpoint = 12 MPa)

2. Operational Guidelines

Do Not:

  • โœ— Rapid pressurization (use โ‰ค 1 MPa/min pressure ramp)
  • โœ— Overpressure at ambient temperature (preheat to โ‰ฅ 100 ยฐC before pressurizing)

4. Failure Case Studies

Case 1: Flange Seal Leak (POSTECH Case)

  • Issue: Helium leak rate surged at 8 MPa
  • Root Cause: Gasket was not annealed; high hardness prevented proper deformation
  • Solution: Switched to HV50 soft copper; leak reduced by 100ร—

Case 2: Tube Fracture (NIMS Japan Lab)

  • Issue: Longitudinal cracking at 12 MPa
  • Root Cause: Subsurface flaw from laser cutting went undetected
  • Improvement: Supplier now must provide fluorescent penetrant inspection report

5. Technical Support

Quartz Tube Supplier | Customizable Tubes & Heaters | GlobalQT
For further consultation based on specific test parameters (e.g., COโ‚‚ phase, ramp rate, etc.), please contact us.

This document should be revised by the experimenter based on specific experimental parameters (e.g., COโ‚‚ phase state, heating rate, etc.).

en_USEnglish
ๆปšๅŠจ่‡ณ้กถ้ƒจ

Request a consultation

We will contact you within 1 working day, please pay attention to the email with the suffix โ€œ@globalquartztube.comโ€