실험실 유리 제품의 세척, 건조 및 사용 설명

This article provides a detailed explanation of the cleaning, drying, and usage methods for laboratory glassware. It is divided into three parts to facilitate understanding and application.

I. Cleaning of Glassware

1. Shaking Water Wash

Basic explanation of the shaking water wash method.

2. Brushing for Stubborn Stains

If there are substances on the inner wall that are not easily removed, use a brush to clean. The process involves:

  • Disposing of the waste liquid first.
  • Adding half the amount of water.
  • Selecting an appropriate brush and holding it correctly to scrub.
  • Repeat the process as necessary until the glassware is thoroughly cleaned.

Cleaning Illustration: (image labeled “Washing 2.1.png”)

3. Final Rinse

After brushing, rinse the glassware by shaking it several times with water. If necessary, use distilled water to rinse three times. In a clean state, the water will spread evenly without forming droplets (as shown in the left image), whereas in an unclean state, water droplets will remain on the surface (as shown in the right image).

If the glassware contains water-insoluble substances like alkalis, carbonates, or basic oxides, add hydrochloric acid first to dissolve them, then rinse with water. If grease or oil is present, use hot sodium carbonate solution followed by brushing. Alternatively, use a brush with a small amount of detergent. For narrow-necked instruments that are difficult to brush, rinse with a small amount of aqua regia or chromic acid solution. If these methods still fail, soak the item in a more concentrated solution and then rinse with water.

Safety Tip: Always dispose of waste liquid before adding water, and avoid cleaning multiple test tubes simultaneously.
Additional Safety Reminder: When handling corrosive solutions such as hydrochloric acid or aqua regia, wear protective gloves and goggles to prevent skin or eye injury.

II. Drying of Glassware

1. Air Drying (Left Image) vs. Oven Drying (Right Image)

Explanation of natural air drying and oven drying methods.

2. Blowing Dry (Left Image) vs. Heated Drying (Right Image)

Explanation of using compressed air and heated air for drying.

3. Airflow Drying (Left Image) vs. Rapid Drying (Right Image)

Explanation of airflow-based drying and rapid drying techniques.

Illustration Suggestion: Consider adding clear diagrams or photographs of each drying method to help users better understand the differences and practical applications.

III. Use of Common Glassware

1. Graduated Cylinder and Measuring Cup

Explanation of the usage guidelines for measuring liquids with graduated cylinders and measuring cups.

2. Pipette

Pipette usage precautions include:

  • Select a pipette of appropriate size based on the volume needed (e.g., for 1.5 ml of liquid, a 2 ml pipette is more accurate than a 5 ml one).
  • When drawing liquid, insert the pipette into the solution to avoid drawing air, which could cause overflow.
  • After removing the pipette from the liquid, wipe the outer wall with filter paper before dispensing the liquid.
  • Do not draw solvent or solution directly from the bottle with the pipette. Any remaining solvent or solution should be disposed of as waste, not returned to the storage bottle.

Illustration Suggestion: Provide an image showing the correct and incorrect methods of pipette usage.

3. Burette

The operation steps include: cleaning → applying Vaseline → leak checking → filling with operating solution → venting the burette → titration.

Safety Tip: When using Vaseline for sealing, ensure that the solution is not contaminated, as this could affect the accuracy of titration.

4. Volumetric Flask

Before using a volumetric flask, check whether its stopper leaks. A qualified stopper should be secured around the bottle neck and should not be replaced arbitrarily. If water droplets remain above the calibration mark on the inner wall, it can affect accuracy, so the flask must be thoroughly cleaned. Any solid substances to be weighed must be dissolved in a small beaker first, then transferred to the volumetric flask after cooling to room temperature. The flask should never be heated or dried in an oven.

Illustration Suggestion: Add an image demonstrating the correct technique for mixing the solution in the volumetric flask.

Additional Tip: Ensure that all volumetric operations are performed at room temperature to maintain solution accuracy.

작성자

  • 캐스퍼 펭

    캐스퍼 펭은 쿼츠 튜브 업계의 노련한 전문가입니다. 10년 이상의 경험을 바탕으로 쿼츠 소재의 다양한 응용 분야에 대한 깊은 이해와 쿼츠 가공 기술에 대한 해박한 지식을 보유하고 있습니다. 캐스퍼는 쿼츠 튜브의 설계 및 제조에 대한 전문 지식을 바탕으로 고객의 고유한 요구 사항을 충족하는 맞춤형 솔루션을 제공할 수 있습니다. 캐스퍼 펭의 전문 기사를 통해 최신 업계 뉴스와 가장 실용적인 기술 가이드를 제공하여 쿼츠 튜브 제품을 더 잘 이해하고 활용할 수 있도록 돕고자 합니다.

    모든 게시물 보기

문의사항 및 지원이 필요하시면 연락주세요

귀하의 요구 사항을 파악한 후 전문 엔지니어가 무료 솔루션을 제작할 것입니다.

영업일 기준 1일 이내에 신속한 응답을 기대합니다. 귀하의 비전을 현실로 바꿔드리겠습니다.

우리는 귀하의 기밀성을 존중하며 모든 정보는 보호됩니다.

ko_KRKorean
滚动至顶部

상담 요청하기

영업일 기준 1일 이내에 연락드리며, 접미사 '@'가 포함된 이메일에 유의하시기 바랍니다.글로벌쿼츠튜브.com"
핵링크betsat
betsat
betsat
홀리건벳
홀리건벳
홀리건벳
채용 정보
채용 정보
채용 정보
카시봄 기리쉬
카시봄 기리쉬
카시봄 기리쉬
xbet
xbet
xbet
그랜드파사벳
그랜드파사벳
그랜드파사벳
이즈미르 시콜로지
크리에이티브 뉴스
디지털 마케팅
라디오 칼라신
라디농카이
게브즈 에스코트
casibom
casibom
외래 문자
엑스트라벳
베트 퍼블릭 기리쉬
csahaber
마타도르 베트 기리쉬
betturkey
casibom
카시봄 귄셀 기리스
casibom
마스바히스 귄셀 기리스
틱톡 동영상 주소
터키어 알타이어 포르노
킹로얄 Vip
카시봄 기리스
아동 포르노 데네메 보너스
아동 포르노 데네메 보너스
이 사이트에는 다음과 같은 보너스가 있습니다.
그랜드파사벳
카시봄 귄셀 기리스카시봄 귄셀 기리스